A fire curtain closes an opening automatically and forms a full compartment separation, without a solid wall or door. Classifications from E 120 to EI 120, spans up to 15 × 7 metres.

Specifications

ClassificationEN 13501-2
E 120, EW 20 – EW 120 and EI 60 – EI 120 (depending on model)
Test standardEN 1634-1
Tested to EN 1634-1; CE marking
Maximum dimensions
Up to 15,000 × 7,000 mm (MEGAFIRE EI 120)
Control
24V tubular motor with CRM control and Gravity Fail-Safe; CBM control cabinet (115/230 V) with UPS backup power for up to 6 hours
Fabric material
Glass-fibre fabric with polyurethane or silicone coating; EI versions multi-layered with intumescent and silica layers

Available models

PhotoModelClassificationDescription
BACHFIRE fire curtain fully closing off a wide passage in a concrete hall
BACHFIREBACHFIRE fire curtain fully closing off a wide passage in a concrete hall
BACHFIREE 120EN 13501-2The standard automatic fire curtain: glass-fibre fabric with polyurethane coating, stitched with reinforced steel wire, on a steel roller Ø 78 mm.
BACHFIRE Z fire curtain closed in a passage with sleek side guides
BACHFIRE ZBACHFIRE Z fire curtain closed in a passage with sleek side guides
BACHFIRE ZE 120 / EW 20EN 13501-2Fire curtain with additional EW 20 performance for situations that require radiation reduction in addition to flame-tightness.
Radiation-reducing BACHFIRE EW fire curtain closed next to an escape route
BACHFIRE EWRadiation-reducing BACHFIRE EW fire curtain closed next to an escape route
BACHFIRE EWEW 120EN 13501-2Limits heat radiation to less than 15 kW/m² at 1 metre from the fabric — for 120 minutes. For escape routes along the curtain.
BACHFIRE EGRESS fire curtain with integrated escape door in the fabric
BACHFIRE EGRESSBACHFIRE EGRESS fire curtain with integrated escape door in the fabric
BACHFIRE EGRESSE 120EN 13501-2Fire curtain with an integrated escape door, so people can still escape after the curtain has closed.
Insulating SUPERFIRE fire curtain with multi-layer fabric over a large opening
SUPERFIREInsulating SUPERFIRE fire curtain with multi-layer fabric over a large opening
SUPERFIREEI 120EN 13501-2Insulating fire curtain that limits heat transfer as well as flames and radiation (EI performance) — without water spray.
Large MEGAFIRE EI 120 fire curtain closing off a very wide industrial opening
MEGAFIRE EI 120Large MEGAFIRE EI 120 fire curtain closing off a very wide industrial opening
MEGAFIRE EI 120EI 120EN 13501-2Heavy five-layer fabric with intumescent and silica layers for large spans up to 15 × 7 metres.
SUPERFIRE Z fire curtain in a building passage
SUPERFIRE ZSUPERFIRE Z fire curtain in a building passage
SUPERFIRE ZEI 120EN 13501-2Insulating version within the Z line: the curtain not only holds back flames but also limits heat transfer, keeping the safe side passable.
MEGAFIRE EI 60 fire curtain above a wide building opening
MEGAFIRE EI 60MEGAFIRE EI 60 fire curtain above a wide building opening
MEGAFIRE EI 60EI 60EN 13501-2Large-format curtain on an 89 mm roller, for openings that outgrow the standard line but need only sixty minutes of insulation.
Horizontal BACHFIRE H fire curtain closing off a floor opening
BACHFIRE HHorizontal BACHFIRE H fire curtain closing off a floor opening
BACHFIRE HEW 60EN 13501-2Horizontal version that closes off floor openings such as voids, shafts and escalator openings — where vertical screening is not possible.

Classifications E, EW and EI explained

The classification tells you what the curtain holds back: E stands for integrity (flame-tightness), EW additionally limits heat radiation, and EI also limits heat transfer. Which class is required depends on the function of the separation and what lies behind it. On the fire safety knowledge page we explain the classifications in detail.

Applications

Fire curtains are used in passages and over large openings in industry and logistics, in facades to prevent fire spread, and around stairwells and atriums. See the solutions by application to explore the possibilities for your building.

Installation and maintenance

Installation is carried out by specialised dealers from our nationwide network, according to the manufacturer's instructions. With a maintenance contract the curtain is periodically inspected and tested, so its operation remains demonstrably assured — as the duty of care in the Dutch building regulations (Bbl) requires.