Rolled-up smoke curtain in a ceiling cassette with the fabric partially unrolled

Smoke curtain for automatic smoke compartmentation

A smoke curtain limits the spread of smoke, the greatest danger in a fire. The fabric sits rolled in a cassette and descends automatically on detection.

Specifications

ClassificationEN 12101-1
DA, DH and DHA (depending on model)
Control
24V tubular motor with CRM control and Gravity Fail-Safe; CBM control cabinet (115/230 V) with UPS backup power for up to 6 hours
Fabric material
Glass-fibre fabric with polyurethane coating on both sides, stitched with Kevlar or steel wire
CertificationEN 12101-1
Tested and CE-marked

Available models

PhotoModelClassificationDescription
BACHSMOKE DA smoke curtain partially descended from a ceiling cassette in an atrium
BACHSMOKE DABACHSMOKE DA smoke curtain partially descended from a ceiling cassette in an atrium
BACHSMOKE DADAEN 12101-1Automatic smoke curtain that descends on detection and limits the spread of smoke. Fabric on a steel roller Ø 78 mm, driven by a 24V tubular motor with Gravity Fail-Safe.
BACHSMOKE DHA smoke curtain with steel side guides and bottom bar in a wide corridor
BACHSMOKE DHABACHSMOKE DHA smoke curtain with steel side guides and bottom bar in a wide corridor
BACHSMOKE DHADH 180 (DHA)EN 12101-1Automatic smoke curtain, tested per the factory documentation as DH 180 to EN 12101-1 and therefore within the DHA classification system: performing for more than 120 minutes under the standard fire curve. Fitted with a galvanised steel head box, side guides and bottom bar for improved smoke sealing.
BACHSMOKE EV smoke curtain descended next to an escape route with emergency exit
BACHSMOKE EVBACHSMOKE EV smoke curtain descended next to an escape route with emergency exit
BACHSMOKE EVDAEN 12101-1Automatic smoke curtain that, in addition to smoke control, allows people to escape — suitable for positions in or near escape routes.
Static BACHSMOKE FIX smoke curtain as a fixed smoke skirt around a roof opening in an industrial hall
BACHSMOKE FIXStatic BACHSMOKE FIX smoke curtain as a fixed smoke skirt around a roof opening in an industrial hall
BACHSMOKE FIXDA / DH 30EN 12101-1Static (fixed) smoke curtain for permanent smoke compartmentation, for example as a fixed smoke skirt under roofs and around voids.
Horizontal BACHSMOKE H smoke curtain extended below a ceiling
BACHSMOKE HHorizontal BACHSMOKE H smoke curtain extended below a ceiling
BACHSMOKE HDA / DH 120EN 12101-1Horizontal version that prevents the vertical spread of smoke through floor openings, for instance above escalators and voids.

Operation and control

The curtain is controlled from the fire alarm system and descends automatically and in a controlled manner on detection. The 24V tubular motor with Gravity Fail-Safe ensures the fabric also closes safely under its own weight during a power failure; the CBM control cabinet with UPS backup bridges up to six hours.

Applications

Smoke curtains are used around atriums and voids, above escalators, in corridor zones and at escape routes. See the solutions for atriums and voids and for stairwells and escape routes to find out which version suits your situation.

Certification and documentation

All BACHSMOKE models are tested to EN 12101-1 and carry CE marking. Smoke leakage performances such as Sa or S200 are separate classifications (EN 1634-3, EN 13501-2) that must be demonstrable for each curtain construction. Test reports, product sheets and installation instructions are available per model; request documentation for your project or specification.

Together on your project

Smoke curtain in your project?

Request your quote here